Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Inquiry For Fire Testing
 
Recommended Service
Hot Fire test center
 
Your location: Home » Fire test center » Railway Component » Text

NFPA 130 (ASTM E 162, ASTM E 662): Fire Test to Railway Components

Zoom  Zoom Issue Date:2011-06-05   Source:Firetc   Author:Firetc   Browse:17802
NFPA 130, This standard shall cover fire protection requirements for underground, surface, and elevated fixed guideway transit and passenger rail systems, including trainways, vehicles, and vehicle maintenance and storage areas, and for life safety from f

Fire test center will provide USA Standard NFPA 130 Fire test to Railway Components

NFPA 130 Fire Test to railway component - Standard
> NFPA 130 : Standard for fixed guideway transit and passenger rail systems.

NFPA 130 Fire Test to railway component – Standard Introduction
This standard shall cover fire protection requirements for underground, surface, and elevated fixed guideway transit and passenger rail systems, including trainways, vehicles, and vehicle maintenance and storage areas, and for life safety from fire in fixed guideway transit and passenger rail system stations, trainways, vehicles, and outdoor vehicle maintenance and storage areas.
The purpose of this standard shall be to establish minimum requirements that will provide a reasonable degree of safety from fire and its related hazards in fixed guideway transit and passenger rail system environments.

NFPA 130 Fire Test to railway component – Test Method:
Category
Function of Material
Required Testing
Test Method
Cushioning
All individual flexible cushioning materials used in seat cushions, mattresses, mattress pads, armrest, crash pads, and grab rail
padding
Surface Flammability
ASTM D 3675
Smoke Density
ASTM E 662
Fabrics
Seat upholstery, mattress ticking and covers, curtains, draperies, window shades, andwoven seat cushion suspensions
Burning behaviour
14 CFR 25
Smoke density
ASTM E 662
Other vehicle
components
Seat and mattress frames, wall and ceiling lining and panels, seat and toilet shrouds,toilet seats, trays and other tables, partitions,
shelves, opaque windscreens, combustible signage, end caps, roof housings, articulation bellows, exterior shells, nonmetallic skirts, and component boxes
and covers
Surface Flammability
ASTM E 162
Smoke Density
ASTM E 662
Thermal and acoustical insulation
Surface Flammability
ASTM E 162
Smoke Density
ASTM E 662
HVAC ducting
Surface Flammability
ASTM E 162
Smoke Density
ASTM E 662
Floor covering
Critical Radiant Flux of Floor-Covering System
ASTM E 648
Smoke Density
ASTM E 662
Light diffusers, windows and transparent plastic windscreens
Surface Flammability
ASTM E162
Smoke Density
ASTM E 662
Elastomers
Window gaskets, door nosings, intercar diaphragms, seat cushion suspension diaphragms, and roof mats
Flame Propagation
ASTM C 1166
Smoke Density
ASTM E 662
Wire and cable
all
Fire test for cable and wire
NFPA 130
Structural
component
Flooring, other
Fire Tests of Building Construction
ASTM E 119

NFPA 130 Fire Test to railway component – Material under Scope
- Rubber Products (Seal and filter
- Melamine foam for thermal insulation
- Sound insulation blanket
- Textile for curtain, seat backing
- Plastic Products (light shade, shell of cell)
- Flooring (glue and adhesive
- Cable
- Sound insulation blanket
- Electrical Device
- Fire-resistance paint
- Fire-redartant adhesive
- Seat (Sponge)

NFPA 130 Fire Test to railway component – Reference Standards
>ASTM C 1166, Standard Test Method for Flame Propagation of Dense and Cellular Elastometric Gaskets and Accessories
>ASTM D 3675, Standard Test Method for Surface Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source
>ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials
>ASTM E 119, Standard Test Method for Fire Tests of Building Construction and Materials
>ASTM E 162, Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source
>ASTM E 648, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source.
>ASTM E 662, Standard Test Method for Specific Optical Densityof Smoke Generated by Solid Materials.
>ASTM E 814, Standard Test Method for Fire Tests of Through-Penetration Fire Stops
>ASTM E 1537, Standard Test Method for Fire Testing of Upholstered Furniture
>ASTM E 1590, Standard Test Method for Fire Testing of Mattresses,

For more detailed information about USA Standard NFPA 130 fire test to Railway Components.
 
 