Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 

DIN EN 50266-2-4 / EN 50266-2-4

Click image to view original picture
Product/Service: DIN EN 50266-2-4 / EN 50266-2-4 
Brand: EcoSafene 
Type: DIN EN 50266-2-4 
Size: EN 50266-2-4 
Unit Price: 500.00USD/M  Inquiry
The min order: 6 M 
Total Supply: 600000 M
Delivery Expiry: Delivery within 3 days after payment from buyer
Validity Period: Longterm Validity
Last Update: 2014-08-19
Browse: 8921
Basic Info of Company
 
 
Product detailed description
 DIN EN 50266-2-4 / EN 50266-2-4 Fire test on bunched cables 

DIN EN 50266-2-4 Fire test on bunched cables - Standard 

DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-4: Procedures –Category C 

Note: The EN 60332-3-24-2010 standard supersedes EN50266-2-4-2001 standard. 

DIN EN 50266-2-4 Fire test on bunched cables - Requirement

For cable diameter ≥ 12 mm; Category C. At the end of the test, the maximum distance of charred part measured and evaluated at the sample of the lower edge of the burner, on both sides of the Have not reached the head height of 2.5 meters.(Refer to DIN 5510-2 test standard)

DIN EN 50266-2-4 Fire test on bunched cables - Reference Standard  

DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.

EN60332-3-24: 2010-08 Test on Electric and Optical Fibre Cables under Fire Conditions Part 3-24: Test For vertical flame spread of vertically---Mounted bunched wires or cables Category C (IEC 60332-3-24:2000 + A1:2008)

DIN EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D

DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods

DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame

DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus

We also can provide the following service of fire test

> Fire test to railway components: EN 45545-2,TB/T 3237,BS 6853, DIN 5510-2, NF F 16-101, UNI CEI 11170-3, NFPA 130, , TB3237,UIC 564-2.

> Fire test to buidling material: EN 13501-1, DIN 4102, BS 476, NF P 92-501, GB 8624

> Fire test to marine equipment: IMO FTPC, Wheelmark, USCG

> Fire test to aircraft material: FAR 25, BSS 7239, BSS 7238, ASTM E 662

> Fire test to interior material of motor vehicles: 95/28/EC, GB 8410, FMVSS 302, ISO 3795

 
More..Other products of this company

[ Product Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]