Supply BS 476-7 Fire Test to Building Material

Click image to view original picture
Product/Service: BS 476-7 Fire Test to Building Material  
Brand: Ecosafene 
Type: BS 476-7 
Size: BS 476-7 
Unit Price: 1900.00USD/PCS  Inquiry
The min order: 1 PCS 
Total Supply: 1000 PCS
Delivery Expiry: Delivery within 3 days after payment from buyer
Validity Period: Longterm Validity
Last Update: 2014-07-22
Browse: 2374
Basic Info of Company
 
 
Product detailed description

BS 476-7 Fire Test to Building Material – Standard

Ecosafene Products Service Co.,Ltd provide BS476-7 fire test service to Building Material .
Ecosafene Products Service(Xiamen) Co., Ltd , the facility of Ecosafene International, is not only the authoritative office of European Standard Institute, European Notified Body for CE marking, but also the global partner of FireTC(www.firetc.com)  which will keep you informed latest news about fire standards and regulation, provide professional technical service of fire test and make you get more business chance.
 
>>> BS 476-7 Fire Test to Building Material – Standard  BS 476-7: Fire Tests on Building materials and structures – Method of test to determine the   
  classification of the surface spread of flame of products
>>> BS 476-7 Fire Test to Building Material – Standard Brief
This Part of BS 476 specifies a method of test for measuring the lateral spread of flame along the surface of a specimen of a product orientated in the vertical position under opposed flow conditions, and a classification system based on the rate and extent of the spread of flame. It provides data suitable for comparing the end-use performances of essentially flat materials, composites or assemblies, which are used primarily as the exposed surfaces of walls or ceilings.

>>>BS 476-7 Fire Test to Building Material – Test Method -Procedure:
 a.) Ignite the pilot flame.
 b.) Remove a specimen construction, including any backing boards, spacers and filler pieces, from the conditioning atmosphere, and within 5 min insert it into the specimen holder in its standby position at 90Ê or more from the test position.
 c.) Within 5 s swing the specimen holder and specimen into the test position, and immediately start the timing mechanism, i.e. start the test.
 d.) Extinguish the pilot flame 1 min after the start of the test.
 e.) Terminate the test when the flame front reaches the 825 mm reference line, or after 10 min has elapsed, whichever is the shorter.
 f.) Swing the specimen holder into its standby position and remove the remains of the specimen construction. Clean any debris from the holder.
 g.) Repeat the procedures given in a) to f) above for each of the remaining specimen constructions.
Classification  Spread of flame at 1.5 min Final Spread of flame
 Limited
mm Limit for one specimen in sample
mm Limit
mm Limit for one specimen in sample
mm
1 165 25 165 25
2 215 25 455 45
3 265 25 710 75
4 Exceeding the limits for class 3

>>> BS 476-7 Fire Test to Building Material – Reference Standard
  BS 476:Fire tests on building materials and structures
  BS 476-3:Fire tests on building materials and structures. Classification and method of test for external fire exposure to roofs
  BS 476-4:Fire tests on building materials and structures - Part 4: Non-combustibility test for materials
  BS 476-5:Fire Tests on Building Materials and Structures Part 5: Method of Test for Ignitability
  BS 476-6:Fire tests on building materials and structures — Part 6: Method of test for fire propagation for products
  BS 476-7:Fire Tests on Building Materials and Structures Part 7: Method of Test to Determine the Classification of the Surface Spread of Flame of Products
  BS 476-20:Fire Tests on Building Materials and Structures Part 20: Method for Determination of the Fire Resistance of Elements of Construction (General Principles)
  BS 476-21:Fire Tests on Building Materials and Structures Part 21: Methods for Determination of the Fire Resistance of Load bearing Elements of Construction
  BS 476-22:Fire Tests on Building Materials and Structures Part 22: Methods for Determination of the Fire Resistance of Non- Load bearing Elements of Construction
 
>>> We also can provide the following service of fire test
> Fire test to railway components: BS 6853, DIN 5510-2, NF F 16-101, UNI CEI 11170-3, NFPA 130, EN 45545-2, UIC 564-2.
> Fire test to buidling material: EN 13501-1, DIN 4102, BS 476, NF P 92-501, GB 8624, GB 20286
> Fire test to marine equipment: IMO FTPC, Wheelmark, USCG
> Fire test to aircraft material: FAR 25, BSS 7239, BSS 7238, ASTM E 662
> Fire test to interior material of motor vehicles: 95/28/EC, GB 8410, FMVSS 302, ISO 3795

We have already provide BS476-7 fire testing services to many clients and have rich experience on it, please contact us, , we will share with you a specific test methods and technical analysis! www.ecosafene.com
 For more detailed information about Standard BS476-7 Fire Test to Building Material. Please contact on info@ecosafene.com or 
Leave message online: http://www.ecosafene.com/EN/plus/consult.php

 

 
More..Other products of this company

[ Product Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]