BS 476-6 Fire Test to Building Material – Standard
Ecosafene Products Service Co.,Ltd provide BS476-6 fire test service to Building Material .
Ecosafene Products Service(Xiamen) Co., Ltd , the facility of Ecosafene International, is not only the authoritative office of European Standard Institute, European Notified Body for CE marking, but also the global partner of FireTC(www.firetc.com) which will keep you informed latest news
>>>BS 476-6 Fire Test to Building Material – Standard
BS 476-6: Fire Tests on Building materials and structures – Method of test for fire propagation for products
>>> BS 476-6 Fire Test to Building Material – Standard Brief
This Part of BS 476 specifies a method of test, the result being expressed as a fire propagation index, that provides a comparative measure of the contribution to the growth of fire made by an essentially flat material, composite or assembly. It is primarily intended for the assessment of the performance of internal wall and ceiling linings.
>>> BS 476-6 Fire Test to Building Material – Test Mehod
1. Once a satisfactory repeatable calibration is achieved, allow the apparatus and specimen holder to cool to ambient temperature, remove a specimen from the conditioning chamber and mount it in the specimen holder. Where necessary, back it with non-combustible packing, previously conditioned, to ensure that when the holder is clamped on to the combustion chamber, the face of the test specimen is in contact with the walls of the combustion chamber.
2. Carry out the test procedure e.
3. Decomposition of the specimen during test may result in the formation of soot deposits on the thermocouple hot junctions, which may interfere with the accurate measurement of gas temperatures. To minimize this effect, clean the thermocouples at least 30 s before every temperature reading after the first 3 min of test, by removing them from the chimney and cleaning them with fine wire wool or a fine wire brush, then replacing them.
4. Record the mV output from the thermocouples of the flue gases throughout the duration of the test.
5. Note the actual mV output at the intervalsand the mV rises above the initial m V reading.
6. Calculate Es, the output from the thermocouples for the test specimen, in mV, by the same method specified for Ec and convert it to temperature rise for the flue gases
7. The determination of the fire propagation index requires results from three specimens, but if any specimen exhibits the behaviour described, test up to a maximum of five specimens in an attempt to obtain three valid test results
>>> BS 476-6 Fire Test to Building Material – Reference Standard
BS 476:Fire tests on building materials and structures
BS 476-3:Fire tests on building materials and structures. Classification and method of test for external fire exposure to roofs
BS 476-4:Fire tests on building materials and structures - Part 4: Non-combustibility test for materials
BS 476-5:Fire Tests on Building Materials and Structures Part 5: Method of Test for Ignitability
BS 476-6:Fire tests on building materials and structures — Part 6: Method of test for fire propagation for products
BS 476-7:Fire Tests on Building Materials and Structures Part 7: Method of Test to Determine the Classification of the Surface Spread of Flame of Products
BS 476-20:Fire Tests on Building Materials and Structures Part 20: Method for Determination of the Fire Resistance of Elements of Construction (General Principles)
BS 476-21:Fire Tests on Building Materials and Structures Part 21: Methods for Determination of the Fire Resistance of Load bearing Elements of Construction
BS 476-22:Fire Tests on Building Materials and Structures Part 22: Methods for Determination of the Fire Resistance of Non- Load bearing Elements of Construction
>>> We also can provide the following service of fire test
> Fire test to railway components: BS 6853, DIN 5510-2, NF F 16-101, UNI CEI 11170-3, NFPA 130, EN 45545-2, UIC 564-2.
> Fire test to buidling material: EN 13501-1, DIN 4102, BS 476, NF P 92-501, GB 8624, GB 20286
> Fire test to marine equipment: IMO FTPC, Wheelmark, USCG
> Fire test to aircraft material: FAR 25, BSS 7239, BSS 7238, ASTM E 662
> Fire test to interior material of motor vehicles: 95/28/EC, GB 8410, FMVSS 302, ISO 3795
We have already provide BS476-6 fire testing services to many clients and have rich experience on it, please contact us, , we will share with you a specific test methods and technical analysis! www.ecosafene.com
For more detailed information
Leave message online: http://www.ecosafene.com/EN/plus/consult.php