Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 

IEC 60695-11-10(UL 94)Fire hazard testing to Plastics Material

Click image to view original picture
Product/Service: Plastics Material 
Brand: CASfire 
Unit Price: 3000.00USD/1  Inquiry
The min order: 1 1 
Total Supply: 10000 1
Delivery Expiry: Delivery within 3 days after payment from buyer
Validity Period: Longterm Validity
Last Update: 2021-07-14
Browse: 985
Basic Info of Company
 
 
Product detailed description
EN 60695-11-10 European Fire Retardant test on Holiday Decorations
IEC 60695-11-10(UL 94)Flammability Classification testing to  Plastics Material
IEC 60695-11-10(UL 94)Fire Retardant Test to  Plastics Material
CASfire Technical Co.,Ltd  have rich experience to provide IEC 60695-11-10(UL 94)Fire Retardant Test to  Plastics Material.
Fire test center provide IEC 60695-11-10(UL 94)Fire hazard testing to Plastics Material.
IEC 60695-11-10(UL 94)Fire Retardant Test to  Plastics Material - Principle
IEC 60695-11-10 Fire hazard testing - Part 11-10: Test flames -50 W horizontal and vertical flame test methods
IEC 60695-11-10(UL 94)Fire Retardant Test to  Plastics Material - Scope
IEC 60695-11-10:2013 specifies small-scale laboratory test procedures intended to compare the burning behaviour of different materials used in electrotechnical products when vertically or horizontally oriented test bar specimens are exposed to a small flame ignition source with a nominal thermal power of 50 W. 
These test methods determine either the linear burning rate or the self-extinguishing properties of materials. 
These test methods are applicable to solid and cellular materials that have an apparent density of more than 250 kg/m3, determined in accordance with ISO 845. 
Two test methods are described. 
Method A is a horizontal burning test and is intended to determine the linear burning rate of materials under specific test conditions. 
Method B is a vertical burning test and is intended to determine whether materials self-extinguish under specific test conditions. 
IEC 60695-11-10 Fire Retardant Test to  Plastics Material- relative standards 
UL 94 Test For Flammability of Plastic Materials for Parts in Devices and Appliances
ISO 4589-2:1996+A1:2005 Plastics -- Determination of burning behaviour by oxygen index -- Part 2: ambient-temperature test
ISO 4589-3:1996 Plastics -- Determination of burning behaviour by oxygen index -- Part 3: Elevated-temperature test 
UL1581:2009 Reference standard fo electrical wires cables,and flexible cords VW-1(clause 1080)
IEC 60332-1-2:2004 Tests on electric and optical fibre cables under fire conditions –Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame
IEC 60332-1-3:2004 Tests on electric and optical fibre cables under fire conditions –Part 1-3:
Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles
IEC 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions –Part 2-2:
Test for vertical flame propagation for a single small insulated wire or cable – Procedure for diffusion flame
IEC 60332-3-21:2000 Tests on electric and optical fibre cables under fire conditions Part 3-21:Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A F/R
IEC 60332-3-22:2009 Tests on electric and optical fibre cables under fire conditions Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A
IEC 60332-3-23:2009 Tests on electric and optical fibre cables under fire conditions Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category B
IEC 60332-3-24:2009 Tests on electric and optical fibre cables under fire conditions Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category C
IEC 60332-3-25:2009 Tests on electric and optical fibre cables under fire conditions Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category D
DIN EN 6059-303 (DRAFT) Aerospace series - Electrical cables, installation; Protection sleeves; Test methods - Part 303: Resistance to fluids
ISO 6722:2006 specifies the dimensions, test methods, and requirements for single-core 60 V cables intended for use in road vehicle applications 
IEC 60695-2-11-2000 (GB 5169.11) Fire hazard testing — Part 2-11: Glowing/hot-wire based test methods — Glow-wire flammability test method for end-products
IEC 60695-2-12-2000 (GB 5169.12) Fire hazard testing — Part 2-12: Glowing/hot-wire based test methods — Glow-wire flammability test method for materials
IEC 60695-2-13-2000 (GB 5169.13) Fire hazard testing — Part 2-13: Glowing/hot-wire based test methods — Glow-wire ignitability test method for meterials
ASTM D 2863 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)
For more detailed information about IEC 60695-11-10(UL 94)Fire hazard testing to Plastics Material.
Please contact firetest@firetc.com or leave inquiry message online.
CASfire Technical Co.,Ltd
8F Building 4, Chinese Academy of Science, 
No.255 South Duiying Road,Jimei, Xiamen 361021, China
Tel: (+86) 0592-3500085 
MP: (+86) 18906059211  
Email: info@casfire.cn
Website: http://www.casfire.cn
 
More..Other products of this company

[ Product Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]