fire resistant cable
1~Section:1.5-800,Cores 1-5
2~1kV,750V and below
3~Power cable,control cable,electric wire
4~ISO9001
Low Smoke Free Halogen Flame Retardant Fire Resistant Wires/Cables
1.Standard
The fire resistant cable electrical and mechanical properties comply with the national or industrial standards
like GB12706, GB9330, GB5023 or JB8734 for the same rated voltage cable. The flame resistant property is
accord with GB/T19666-2005 or IEC60332-3. The fire resistant property is accord with GB/T or IEC60331.
2. Application
The products are suitable to be used in those places of the flame-retardant, fire-resistant , low-smoke,no-halogen and etc,with the requirements of the fireproof , such as the big capacity power station,nuclear plant,subway and high building as well as the population densed section and etc.
3. Model&De
fire resistant type |
Flame resistant fire resistant type |
De |
NH-BV |
ZR-NH-BV |
Cu conductor PVC insulated (flame resistant) fire-resistant cables |
NH-BVV |
ZR-NH-BVV |
Cu conductor PVC insulated and sheathed (flame resistant) fire-resistant cables |
NH-KVV |
ZR-NH-KVV |
Cu conductor PVC insulated and sheathed (flame resistant) fire-resistant control cables |
NH-KVV22 |
ZR-NH-KVV22 |
Cu conductor PVC insulated and sheathed internal steel tape armored (flame resistant) fire-resistant control cables |
NH-VV |
ZR-NH-VV |
Cu conductor PVC insulated and sheath (flame resistant)fire-resistant power cables |
NH-VV22 |
ZR-NH-VV22 |
Cu conductor PVC insulated and sheathed internal steel tape armored(flame resistant) fire-resistant power cables |
NH-YJV |
ZR-NH-YJV |
Cu conductor XLPE insulated and PVC sheathed (flame resistant) fire-resistant power cables |
NH-YJV22 |
ZR-NH-YJV22 |
Cu conductor XLPE insulated and PVC sheathed internal steel tape armored (flame resistant) fire-resistant power cables |
flame resistant XLPE insulated cable series
Type |
De |
Application |
|
Cu Core |
Al Core |
||
YJV ZR-YJV |
YJLV ZR-YJLV |
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable |
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 |
YJLV22 ZR-YJLV22 |
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable |
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 |
YJLV32 ZR-YJLV32 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 |
YJLV42 ZR-YJLV42 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force |
4. test report
name: PVC insulated&sheathed copper wire weaving screen flame retardant A grade control cable
model ZA-KVVP-450/750V 7*1.5mm2