a. Built-in microprocessor
b. Intelligentized fire alarm and fault judgment
c. Field setup of two levels of sensitivity
Brief Introduction
|
TY-HS-BK801Ex Line Beam Smoke Fire Detector is an intrinsic satety reflection line infrared beam smoke fire detector which is in accordance with the national standard of GB14003-2005, GB3836.1-2000 Electrical Apparatus for Explosive Gas Atmosphere Part 1: General Requirement, and GB3836.4-2000 Electrical Apparatus for Explosive Gas Atmosphere Part 4: Intrinsic Safety Type “i” with Exd[ia]II CT6 as the Flameproof Mark. The product is applicable to Zone 1 and Zone 2 explosion prevention places with explosion prevention requirements in the oil, chemical industries, etc. The detector contains a group of alarm passive normally open contacts and a group of fault alarm normally closed contacts as well as 0-20mA standard signal output to be conveniently connected with the fire alarm system and DCS system of plants of fire fighting equipment. |
Characteristics |
- Wide operating voltage range and wide protective area
- Built-in microprocessor, intelligentized fire alarm and fault judgment - Self-diagnosis capability, monitoring of faults in the detector - Field setup of two levels of sensitivity - Easy integration of the transmitting part and the receiving part, simple and convenient installation, good light path collimation - Fire alarm and fault passive output contacts and standard 4-20mA standard power supply output - Smart design of the detection light path, high antijamming performance, seal protocol, corrosion protection and waterproof performance - Automatic calibration function to enable a single person to complete debug within a short time, simple operation - Automatic compensation function, and automatic compensation for factors of received signal reduction such as dust pollution, position deflection, ageing of the transmitting tube, etc. to some extent |
Main Technical Parameters |
- Source Voltage: DC16V~DC28V(supplied by the safety grating) - Debug Current: ≤20mA - Monitoring Current: ≤12mA - Alarm Current: ≤24mA - Protective Grade of the Casing: IP54 - Flameproof Mark: ExibII BT6 - Standards: GB3836.1-2000 GB3836.4-2000 GB14003-2005 - The internal parameters of the safety grating: Ui =28V, Ii=93mA, Ci≈0uF, Li≈0mH Pi=O.65W - Indicator Lamps: normal monitoring status: the green indicator lamp flashes. Debugging status: the green, red and yellow indicator lamps light up or flash in a specific mode, and see Debug in the download data for detailed information. Fire Alarm: the red indicator lamp keeps lighting; the yellow indicator lamp blacks out. Fault status: the yellow indicator lamp keeps lighting If the light path is completely blocked, the detector reports a fault and the yellow indicator lamp lights up. - Protective Area: the maximal protective area of the detector 14 x 100=1400m2, maximal width 14m - Ambient Environment: temperature: -20°C~+60°C Relative Humidity ≤95% without condensation - External Dimensions: length x width x thickness=206mm x 94mm x 135mm |