25kv xlpe power cable
1. cheaper price, good quality
2. We are OEM
3.Ship the world and huge inventory
4.13 years experience
copper wire Fire Resistant 25kv xlpe Power Cable
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 0.6/1kV 3.6/6kV.
4. PVC or PE sheathed.
5. Number of cable cores: one core (Single core), two cores (Double cores), three cores,
Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),
Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).
6. Standards: Chinese national standard GB 12706 and GB 12666.6(equivalent to IEC 60502 and IEC 60331)
IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. or other special characteristics as customers request.
Cable Types, Names and Application
Type |
De |
Application |
|
Cu Core |
Al Core |
||
YJV ZR-YJV |
YJLV ZR-YJLV |
Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable |
Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 |
YJLV22 ZR-YJLV22 |
Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable |
Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 |
YJLV32 ZR-YJLV32 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 |
YJLV42 ZR-YJLV42 |
Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable |
Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |
1 conductor 2 insulation 3 tape 4 inner covering 5 armor 6 filler 7 over sheathed
Application conditions
1. The long-time permissible operation temperature of conductor shall not be higher than 70oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 160°C.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0°C.
If so, the cable should be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5. Light weight, perfect bending properties, installed and maintained easily and conveniently.