Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Post InformationYour location: Home » Product » FR E&E Equipment » FR Wire & Cable »

Supply PVC insulated copper core fire resistant wire

Click image to view original picture
Product/Service: PVC insulated copper core fire resistant wire  
Unit Price: Negotiating  Inquiry
The min order:  
Total Supply:
Delivery Expiry: Delivery within 3 days after payment from buyer
Validity Period: Longterm Validity
Last Update: 2014-05-22
Browse: 1268
Basic Info of Company
 
 
Product detailed description

1.Copper wire,PVC Insulated
2.Different colors,Prompt delivery
3.ISO,CCC certifications
4 OEM offered
5.fire resistant

PVC insulated copper core fire resistant wire

Specification:

1.   PVC insulated coper wire,fire resistant.

2. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.

3. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
4. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25mm or above. If the diameter of cable and wires is above 25mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.

Type

Name

Laying Site and Requirements

 Long-time Permissible Working Temperature of Conductor

227IEC01/05 NH-BV

Copper Conductor,PVC Insulated Electrical Wire

Fixed laid in the circumstance of indoor, conduit etc.

70°C

NH-BV

                 Nominal section (mm²)

               Core Structure No/Dia. (mm)

1.5

1/1.38

2.5

1/1.78

4

1/2.25

6

1/2.76

10

7/1.35

16

7/1.70

25

7/2.14

35

7/2.52

50

19/1.78

70

19/2.14

95

19/2.52

120

37/2.03

150

37/2.25

185

37/2.52

240

61/2.25

Type

Name

Laying Site and Requirements

 Long-time Permissible Working Temperature of Conductor

227IEC01/05 BV 

Copper Conductor,PVC Insulated Electrical Wire

Fixed laid in the circumstance of indoor, conduit etc.

70°C

BV

Nominal section (mm²)

Core Structure No/Dia.(mm)

 

1.5

1/1.38

 

2.5

1/1.78

 

4

1/2.25

 

6

1/2.76

 

10

7/1.35

 

16

7/1.70

 

25

7/2.14

 

35

7/2.52

 

50

19/1.78

 

70

19/2.14

 

95

19/2.52

 

120

37/2.03

 

150

37/2.25

 

185

37/2.52

 

240

61/2.25

 