EN 50306-1 Cables of Thin wall Part 1: General requirements

Zoom  Zoom Issue Date:2020-05-07   Browse:563
 
EN 50306-1 Cables of Thin wall Part 1: General requirements – Standard

EN 50306-1 Railway applications - Railway rolling stock cables having special fire performance -Thin wall Part 1: General requirements

EN 50306-1 Cables of Thin wall Part 1: General requirements – Scope
EN 50306-1 specifies the general requirements applicable to the cables given EN 50306-2, EN 50306-3 and EN 50306-4. It includes the detailed requirements for S1 and S2 sheathing materials and other components called up in the separate Parts.

NOTE 1 Detailed requirements for insulation systems are given in EN 50306-2.

In particular EN 50306-1 specifies those requirements relating to fire safety which enable the cables to satisfy Hazard Levels 2, 3 or 4 of EN 45545-1.

NOTE 2 Requirements for the emission of smoke and gases are not specified for Hazard Level 1 of EN 45545-1.

These cables are rated for occasional thermal stresses causing ageing equivalent to
continuous operational life at temperatures of 90 °C or 105 °C dependent upon the sheath
system type. These temperatures are based upon an acceptance test, using long-term thermal endurance ageing at 110 °C and 125 °C respectively, and extrapolation of data to
20000 h. The maximum temperature for short circuit conditions is 160℃ based on a
duration of 5 s.

EN 50306-1 Cables of Thin wall Part 1: General requirements – Reference standards
EN 45545-1 Railway applications - Fire protection of railway vehicles Part 1: General
EN 50264-1 Railway applications - Railway rolling stock cables having special fire
performance - Standard wall - Part 1: General requirements
EN 50305 Railway applications - Railway rolling stock cables having special fire
performance - Test methods
EN 60811-1-1 Insulating and sheathing materials of electric and optical cables -
Common test methods - Part 1-1: General application – Measurement of thickness and overall dimensions - Tests for determining the mechanical properties

 
 