Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Inquiry For Fire Testing
 
Recommended Service
Hot Fire test center
 
Your location: Home » Fire test center » Standards & Regulation » USA » Text

ASTM F1695 Standard Test Method for Performance of Underfired Broilers

Zoom  Zoom Issue Date:2012-02-08   Browse:864
ASTM F1695下烤式烘烤炉性能的标准试验方法
ASTM F1695 Standard Test Method for Performance of Underfired Broilers
ASTM F1695下烤式烘烤炉性能的标准试验方法

The energy input rate test is used to confirm that the underfired broiler is operating properly prior to further testing.
Temperature distribution of the broiling area may be used by food service operators to select an underfired broiler with the desired temperature gradients.
Preheat energy and time can be useful to food service operators to manage energy demands and to know how quickly the underfired broiler can be ready for operation.
Cooking energy efficiency is a precise indicator of underfired broiler energy performance under various loading conditions. This information enables the food service operator to consider energy performance when selecting an underfired broiler.
Production capacity allows the food service operator to select an underfired broiler that meets their food output requirements.
1. Scope
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler and understand its energy performance.
1.2 This test method is applicable to gas and electric underfired broilers.
1.3 The underfired broiler can be evaluated with respect to the following (where applicable):
1.3.1 Energy input rate (see 10.2),
1.3.2 Temperature distribution across the broiling area (see 10.3),
1.3.3 Preheat energy and time (see 10.4),
1.3.4 Pilot energy rate, if applicable (see 10.5),
1.3.5 Cooking energy rate (see 10.6), and
1.3.6 Cooking energy efficiency and production capacity (see 10.7).
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
A36/A36M Specification for Carbon Structural Steel
D3588 Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels
ANSI Standard
ANSIZ83.11 American National Standard for Gas Food Service Equipment
AOAC Documents
AOACOfficialAction96 Fat (Crude) or Ether Extract in Meat
ASHRAE Document
ASHRAEGuideline2-198 (RA90) Engineering Analysis of Experimental Data
Other Document
DevelopmentandValida
Index Terms
cook time; energy efficiency; performance; test method; underfired broiler; Cooking energy efficiency (CEE); Cooking/food service equipment; Cooking/food service equipment performance; Energy efficiency; Underfired broilers;
 
 
[ Fire test center Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]

 

 
 
Home | About us | Contact | Terms & Conditions | Copyright | Site Map | Friend link | Guestbook | Old Version | 闽ICP备09009213号