ASTM E1513喷涂耐火材料应用(SFRMs)

Zoom  Zoom Issue Date:2012-02-08   Browse:865
ASTM E1513喷涂耐火材料应用(SFRMs)
ASTM E1513  Standard Practice for Application of Sprayed Fire-Resistive Materials (SFRMs)
ASTM E1513喷涂耐火材料应用(SFRMs)
This practice is intended for use by the material specifier, general contractor, applicator, or any individual group requiring information regarding the application of SFRM.
This practice is not intended to replace the manufacturers' application instructions.
1. Scope
1.1 This practice covers guidelines for application of sprayed fiber and cementitious fire-resistive materials.
1.2 This practice is general in nature. It is not intended to cover all requirements for application.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10 and 14.1.2.

2. Referenced Documents (purchase separately)
ASTM Standards
E119 Test Methods for Fire Tests of Building Construction and Materials
E605 Test Methods for Thickness and Density of Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members
E631 Terminology of Building Constructions
E736 Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members
E759 Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members
E760 Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members
E1368 Practice for Visual Inspection of Asbestos Abatement Projects
Index Terms
application; sprayed cementitious material; sprayed fire-resistive materials; sprayed mineral fiber material; Application; Installation--building materials/applications; Sprayed fire-resistive materials (SFRMs) ;

 
 