Your location: Home » Fire test center » Standards & Regulation » USA » Text

ASTM D2522 Standard Test Method for Chlorine Content of Polybutenes Used for Electrical Insulation

Zoom  Zoom Issue Date:2012-02-10   Browse:814
ASTM D2522 电绝缘用聚丁烯中氯含量的测试方法

ASTM D2522 Standard Test Method for Chlorine Content of Polybutenes Used for Electrical Insulation
ASTM D2522 电绝缘用聚丁烯中氯含量的测试方法


Chlorine is normally present in polybutenes in small amounts, usually below 50 ppm, as organically bound chlorine. Inorganic chloride is normally not present.
Note 1—The qualitative presence or absence of inorganic chloride may be tested by Test Method D 878.
1. Scope
1.1 This test method describes the determination of the total chloride content of polybutenes used for electrical insulation.
1.2 Warning—Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA’s website (http://www.epa.gov/mercury/faq.htm) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited by state law.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazards information, see Section 8.

2. Referenced Documents (purchase separately)
ASTM Standards
D878 Test Method for Inorganic Chlorides and Sulfates in Insulating Oils
D1193 Specification for Reagent Water
Index Terms
chlorine; electrical; insulating; insulation; polybutenes; Chlorine content; Electrical insulating materials; Electrical insulating oils; Insulation; Polybutylene (PB);
 
 
[ Fire test center Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]

 

 
 
Home | About us | Contact | Terms & Conditions | Copyright | Site Map | Friend link | Guestbook | Old Version | 闽ICP备09009213号
©2013-2015 FIRETC.NET All Rights Reserved   ICP:闽ICP备09009213号-4